banner



How Do You Service The Ironton Horizontal Electric Log Splitter — 5-ton

Reading Fourth dimension: seven minutes

Last Updated on January 11, 2022 by

Troubleshooting your log splitter really isn't as daunting a task every bit you'd think it'd exist. Thanks to the great blueprint of our log splitters, pretty much zip tin go incorrect which is unfixable. Nosotros stock all the spare parts you lot could ever need, but start, we need to work out the problem.

Before diving into how to fix your log splitter issues, let's encompass the different means can neglect.

There are four principal categories of troubleshooting; ability issues, log splitter ram failing to move correctly, oil leakage or the log splitter failing to split logs.

If your log splitter is much like triggers broom and you want to upgrade – yous can find our option of award-winning log splitters on our website.

What this article covers:

  • Is my log splitter broken?
  • Is my log splitter suffering from power problems?
  • My log splitter is tripping the RCD
  • Why isn't my log splitter ram returning?

Is my log splitter broken?

Information technology may oftentimes announced every bit though something critical has afflicted your log splitter, such as the ram declining to move or it appears equally though there'south no ability getting to the log splitter. More oftentimes than not, there are small errors that can exist easily fixed.

Allow'south look into some quick fixes which will quickly tell u.s.a. if the log splitter is indeed cleaved.

If you're not comfortable playing around with your log splitter – let u.s. take a expect for yous. We offer a log splitter repair service, no matter the make. We offering a full repair of your log splitter. This includes collecting your auto, repairing information technology in our workshop and delivery back to yourself. The repair may include a full strip-down, rebuild or plumbing equipment replacement parts.

If you like to tinker and fix with your ain easily – permit'southward move on with our top troubleshooting tips.

Quick Prepare #one: Handle Issue

This may sound airheaded or obvious, but trust the states when nosotros say that this is actually a common error when operating the log splitter.

Check that the plastic knob of the lever is screwed on fully. If this becomes unscrewed it then prevents the lever from beingness pushed right down, and this prevents the log splitter from operating.

Video demonstrating how to fix a log splitter handle

Quick Set up #2: Depression Oil

The oil level in your log splitter may be running depression, y'all can check this past using the dipstick. Yous can too run a quick test by raising the front end end of the log splitter on a block of wood or something similar. If you raise the front of the log splitter and the log splitter then starts operating as normal, and then this is a clear sign that you are low on oil.

Quick Fix #iii: Log Splitter Pointing Downhill

This is similar to the last, only when the log splitter is pointing downhill it struggles to circulate the fluid right around the machine. This causes it to neglect when operating.

The log splitter should always exist operated on level footing or be pointing uphill. If your log splitter is failing to divide any logs, 90% of the fourth dimension this volition be the issue. If the log splitter is not pointing downhill and so it'due south probable low oil.

Log Splitter Ability Issues

At present that nosotros've covered the most common problems and quick fixes. Let's look at some of the more rare problems which tin impact the functioning of the log splitter.

Gentle Humming Noise (not operational)

A humming dissonance will consequence in the log splitter blowing a fuse and typically means that the motor is tight.

First, plow the log splitter over and shut off the air vent, remove the motor and pump 3 x 13mm headed bolts and i 10 support commodities.

Place the log splitter back upright and try the splitter again, if it produces the same noise then loosen the bolts a little from the end of the pump (13mm) and endeavour over again.

No power to the motor

Fuse diddled or RCD Tripped

Offset, cheque the fuse in the plug. If this is blown then supersede it with a working thirteen amp fuse, we besides recommend installing a 13 amp slow accident fuse which you can purchase directly from our website.

You should too check the RCD for the ring chief has not tripped. If the RCD has tripped, try the machine on a dissever ring chief.

If the RCD repeatedly trips then unplug all other equipment from socks on the ring main and switch these sockets off. You tin can then effort to start the motor.

Capacitor Failure

Some other possibility is that the capacitor in the electrical motor has failed from misuse over time.

The capacitor in the electric motor can fail from misuse over fourth dimension. When operating the log splitter, we strongly advise that y'all press the power push button earlier operating the lever, this allows fourth dimension for the motor to gather speed before attempting to split logs.

Pressing the lever before the button tin also often result in blown fuses.

There are many different reasons why in that location may not exist any power to your log splitter:

If you're using an extension lead, ensure that the extension cable itself is a wider diameter than the power atomic number 82 of the electric log splitter.

As stated previously, the capacitor failing will too finish the motor from starting upwardly. Later on you have checked the previous solutions, unplug the log splitter from the mains. So remove the vi screws on the outside of the switch cover, accept the switch encompass off and you volition and then run into the capacitor.

Electric Log Splitter Capacitor, 2200W Motor, 2300W Motor

If the capacitor has failed, you lot will sometimes see burn marks on the capacitor itself.

Replacement capacitors are available on our website – Click here to purchase.

Log Splitter consistently trips RCD or blows a fuse

There are a few unlike fixes to this;

Information technology'due south possible that the motor is jammed. First, check that the motor turns freely. You can do this by removing the black fan comprehend, then information technology should be possible to turn the fan with slight force per unit area from one finger. If this isn't possible, check for obstructions of the fan.

Some other possibility is that the operating lever is loose or non bent correctly, this would prevent the valve from operating correctly. To fix this, check that the face of the lever that operates the valve is bent through a full xc degrees in relation to the mounting face. If not, remove the lever and correct the bend in a vice.

Pump gears binding is an issue that can sometimes present itself within log splitter which would cause a trip. This is easily fixed by loosening each of the 6 bolts on the back of the pump by ¼ of a plow and then checking to see if the motor turns freely.

Pump gears can likewise get jammed. To set this you should remove the 6 bolts from the pump and split up the motor and pump. You tin then check the gears for any silicone sealant or other cloth. When y'all're reassembling, the torque for the bolts is 12 ft-lb, 16 N m.

Log Splitter Ram

If the ram of the log splitter is not returning fully or is jerking upon return, there are a couple of fixes y'all can perform to get it back up and running smoothly.

First, check that the moving railroad vehicle isn't obstructed. Y'all can do this by checking underneath the blade/pusher and down the sides of the wagon for whatsoever splinters of forest that may exist obstructing the carriage.

Besides bank check that the plastic spacers underneath the blade, between the railroad vehicle and the underside of the splitter, accept non been dislodged.

This i is fairly simple to figure out but bank check the log bed of the splitter for a build-upward of sap. You lot can then also apply a sparse layer of grease to the bed to let it to operate more than smoothly.

In social club to fix this issue, utilize the ram stop to lock the ram in a position most 150mm forrad. Remove the iv bolts holding the DuoCut blade or pusher to the carriage and remove the blade/pusher. Unlock the ram stop, if the carriage returns so the arms are bent.

Y'all can cheque the amount of bend with a straight edge, if it is less than 5mm then you may exist able to straighten them in a vice.

Another possibility is that the ram is bent. Remove the DuoCut bract from the splitter. If the ram does non return after removing the DuoCut blade, loosen the 2 rear lock basics on the railroad vehicle arms and remove the 2 nuts in front of the crosspiece. You can and so remove the carriage from the log splitter. If the ram does non return so the next part is a bit tricky so give us a telephone call.

How Do You Service The Ironton Horizontal Electric Log Splitter — 5-ton,

Source: https://forest-master.com/2020/09/03/troubleshooting-electric-log-splitter/